Vulnerability · Published Jun 1, 2026 · Assigned by ENISA

CVE-2026-25599Missing authentication and clear‑text data transmission affecting Orca heat pumps

Medium 6.3

In plain English

A medium-severity cross-site scripting in Orca heat pump from Orca Energy. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.1% (higher than 2% of all known vulnerabilities).

Severity (CVSS 3.1)6.3Medium
Exploit odds (30 days)0.1%top 98.5% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.

Affected products (as reported)

VendorProductVersions
Orca Energy Orca heat pump 0 – before 2.1.0
Orca Energy Orca user portal 0 – before 1.19

Weakness: CWE-79, CWE-306, CWE-319 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L

References