Vulnerability · Published Nov 17, 2025 · Assigned by siemens

CVE-2025-40936

High 7.8

In plain English

A high-severity out-of-bounds read in PS/IGES Parasolid Translator Component from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.2% (higher than 10% of all known vulnerabilities).

Severity (CVSS 3.1)7.8High
Exploit odds (30 days)0.2%top 89.8% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

A vulnerability has been identified in PS/IGES Parasolid Translator Component (All versions < V29.0.258), Simcenter Femap (All versions < V2512.0003), Solid Edge (All versions < V226.00 Update 03). The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755)

Affected products (as reported)

VendorProductVersions
Siemens PS/IGES Parasolid Translator Component 0 – before V29.0.258
Siemens Simcenter Femap 0 – before V2512.0003
Siemens Solid Edge 0 – before V226.00 Update 03

Weakness: CWE-125 · Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

References