Vulnerability · Published Jul 3, 2025 · Assigned by SICK AG
CVE-2025-27460CVE-2025-27460
High 7.6
In plain English
A high-severity security flaw in Endress+Hauser MEAC300-FNADE4 from Endress+Hauser. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.1% (higher than 3% of all known vulnerabilities).
Official description
The hard drives of the device are not encrypted using a full volume encryption feature such as BitLocker. This allows an attacker with physical access to the device to use an alternative operating system to interact with the hard drives, completely circumventing the Windows login. The attacker can read from and write to all files on the hard drives.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Endress+Hauser | Endress+Hauser MEAC300-FNADE4 | vers:all/* |
Weakness: CWE-312 · Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
References
- https://www.endress.com x_Endress+Hauser
- https://sick.com/psirt x_SICK PSIRT Security Advisories
- https://www.cisa.gov/resources-tools/resources/ics-recommended-practices x_ICS-CERT recommended practices on Industrial Security
- https://www.first.org/cvss/calculator/3.1 x_CVSS v3.1 Calculator
- https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0008.json x_The canonical URL.
- https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0008.pdf vendor-advisory