Vulnerability · Published Dec 2, 2025 · Assigned by INCIBE
CVE-2025-11784Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
High 8.5
In plain English
A high-severity stack buffer overflow in Circutor from SGE-PLC1000 SGE-PLC50. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.4% (higher than 34% of all known vulnerabilities).
Official description
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| SGE-PLC1000 SGE-PLC50 | Circutor | 9.0.2 |
Weakness: CWE-121 · Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H