Vulnerability · Published Mar 27, 2024 · Assigned by VulDB
CVE-2024-3008Tenda FH1205 execCommand formexeCommand stack-based overflow
High 8.8
In plain English
A high-severity stack buffer overflow in FH1205 from Tenda. Proof-of-concept exploit code is public. The chance it is exploited in the next 30 days is estimated at 1.7% (higher than 77% of all known vulnerabilities).
Official description
A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Affected products (as reported)
Weakness: CWE-121 · Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
References
- VDB-258294 | Tenda FH1205 execCommand formexeCommand stack-based overflow vdb-entry, technical-description
- VDB-258294 | CTI Indicators (IOB, IOC, IOA) signature, permissions-required
- Submit #301487 | Tenda FH1205 V2.0.0.7(775) buffer overflow third-party-advisory
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formexeCommand.md exploit