Vulnerability · Published Feb 13, 2024 · Assigned by siemens
CVE-2024-23802
High 7.8
In plain English
A high-severity out-of-bounds read in Tecnomatix Plant Simulation V2201 from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.2% (higher than 11% of all known vulnerabilities).
Official description
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Tecnomatix Plant Simulation V2201 | 0 – before V2201.0012 |
| Siemens | Tecnomatix Plant Simulation V2302 | 0 – before V2302.0006 |
Weakness: CWE-125 · Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C