Vulnerability · Published Dec 12, 2023 · Assigned by siemens
CVE-2023-48429
Low 2.7
In plain English
A low-severity security flaw in SINEC INS from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.6% (higher than 48% of all known vulnerabilities).
Severity (CVSS 3.1)2.7Low
Exploit odds (30 days)0.6%top 51.8% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known
Official description
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.
Affected products (as reported)
Weakness: CWE-394 · Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C