Vulnerability · Published Nov 14, 2023 · Assigned by vmware

CVE-2023-34060

Critical 9.8

In plain English

A critical-severity security flaw in VMware Cloud Director Appliance (VCD Appliance). There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.3% (higher than 72% of all known vulnerabilities).

Severity (CVSS NVD)9.8Critical
Exploit odds (30 days)1.3%top 28.5% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).

Affected products (as reported)

VendorProductVersions
n/a VMware Cloud Director Appliance (VCD Appliance) 10.5 if upgraded from 10.4.x or below.

References