Vulnerability · Published Jun 13, 2023 · Assigned by siemens

CVE-2023-25910

Critical 10.0

In plain English

A critical-severity code injection in SIMATIC PCS 7 from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.0% (higher than 63% of all known vulnerabilities).

Severity (CVSS 3.1)10.0Critical
Exploit odds (30 days)1.0%top 37.0% of all CVEs
Exploited in the wildNo reportsnot in CISA KEV
Attack toolingNoneno public tooling known

Official description

A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.

Affected products (as reported)

VendorProductVersions
Siemens SIMATIC PCS 7 0 – before V9.1 SP2 UC04
Siemens SIMATIC S7-PM 0 – before V5.7 SP1 HF1
Siemens SIMATIC S7-PM 0 – before V5.7 SP2 HF1
Siemens SIMATIC STEP 7 V5 0 – before V5.7

Weakness: CWE-94 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:T/RC:C

References