Vulnerability · Published Dec 13, 2022 · Assigned by siemens
CVE-2022-46349
High 7.8
In plain English
A high-severity out-of-bounds read in Parasolid V33.1 from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.5% (higher than 45% of all known vulnerabilities).
Official description
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Parasolid V33.1 | All versions < V33.1.264 |
| Siemens | Parasolid V34.0 | All versions < V34.0.252 |
| Siemens | Parasolid V34.1 | All versions < V34.1.242 |
| Siemens | Parasolid V35.0 | All versions < V35.0.170 |
| Siemens | Solid Edge SE2022 | All versions < V222.0MP12 |
| Siemens | Solid Edge SE2022 | All versions |
| Siemens | Solid Edge SE2023 | All versions < V223.0Update2 |
Weakness: CWE-125 · Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C