CVE-2025-58780High 7.2index.em7 in ScienceLogic SL1 before 12.1.1 allows SQL Injection via a parameter in a request. NOTE: this is disputed by the Supplier because it "inaccurately describes the vulnerability."0.2%
CVE-2022-48604High 8.8A SQL injection vulnerability exists in the “logging export” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the inj0.7%
CVE-2022-48603High 8.8A SQL injection vulnerability exists in the “message viewer iframe” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for 0.7%
CVE-2022-48602High 8.8A SQL injection vulnerability exists in the “message viewer print” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for t0.7%
CVE-2022-48601High 8.8A SQL injection vulnerability exists in the “network print report” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for t0.7%
CVE-2022-48600High 8.8A SQL injection vulnerability exists in the “notes view” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the injecti0.7%
CVE-2022-48599High 8.8A SQL injection vulnerability exists in the “reporter events type” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for t0.7%
CVE-2022-48598High 8.8A SQL injection vulnerability exists in the “reporter events type date” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows 0.7%
CVE-2022-48597High 8.8A SQL injection vulnerability exists in the “ticket event report” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for th0.7%
CVE-2022-48596High 8.8A SQL injection vulnerability exists in the “ticket queue watchers” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for 0.7%
CVE-2022-48595High 8.8A SQL injection vulnerability exists in the “ticket template watchers” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows f0.7%
CVE-2022-48594High 8.8A SQL injection vulnerability exists in the “ticket watchers email” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for 0.7%
CVE-2022-48593High 8.8A SQL injection vulnerability exists in the “topology data service” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for 0.7%
CVE-2022-48592High 8.8A SQL injection vulnerability exists in the vendor_country parameter of the “vendor print report” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to0.7%
CVE-2022-48591High 8.8A SQL injection vulnerability exists in the vendor_state parameter of the “vendor print report” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a0.7%
CVE-2022-48590High 8.8A SQL injection vulnerability exists in the “admin dynamic app mib errors” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allo0.7%
CVE-2022-48589High 8.8A SQL injection vulnerability exists in the “reporting job editor” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for t0.7%
CVE-2022-48588High 8.8A SQL injection vulnerability exists in the “schedule editor decoupled” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows 0.7%
CVE-2022-48587High 8.8A SQL injection vulnerability exists in the “schedule editor” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the in0.7%
CVE-2022-48586High 8.8A SQL injection vulnerability exists in the “json walker” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the inject0.7%
CVE-2022-48585High 8.8A SQL injection vulnerability exists in the “admin brand portal” feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a SQL query. This allows for the0.7%
CVE-2022-48584High 8.8A command injection vulnerability exists in the download and convert report feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a shell command. This1.6%
CVE-2022-48583High 8.8A command injection vulnerability exists in the dashboard scheduler feature of the ScienceLogic SL1 that takes unsanitized user‐controlled input and passes it directly to a shell command. This allows 1.6%
CVE-2022-48582High 8.8A command injection vulnerability exists in the ticket report generate feature of the ScienceLogic SL1 that takes unsanitized user controlled input and passes it directly to a shell command. This allo1.6%
CVE-2022-48581High 8.8A command injection vulnerability exists in the “dash export” feature of the ScienceLogic SL1 that takes unsanitized user controlled input and passes it directly to a shell command. This allows for th1.6%
CVE-2022-48580High 8.8A command injection vulnerability exists in the ARP ping device tool feature of the ScienceLogic SL1 that takes unsanitized user controlled input and passes it directly to a shell command. This allows1.5%