Vulnerability · Published May 28, 2026 · Assigned by icscert

CVE-2026-9039Initialization of a resource with an insecure default in XCharge C6

High 8.6

In plain English

A high-severity security flaw in C6 from XCharge. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.2% (higher than 10% of all known vulnerabilities).

Severity (CVSS 4.0)8.6High
Exploit odds (30 days)0.2%top 90.3% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

A configuration weakness in the device’s remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default administrative credential. A malicious device physically connected to the charging interface could leverage this misconfiguration to obtain full administrative access.

Affected products (as reported)

VendorProductVersions
XCharge C6 0 – before May_22_2026

Weakness: CWE-1188 · Vector: CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H