Vulnerability · Published Mar 5, 2026 · Assigned by Gridware
CVE-2026-29127Incorrect Permission Assignment(777) on `monitor` Users Home Directory Containing SUID Root Binaries in IDC SFX2100
Critical 9.2
In plain English
A critical-severity privilege mismanagement in SFX2100 Satellite Receiver from International Datacasting Corporation. Proof-of-concept exploit code is public. The chance it is exploited in the next 30 days is estimated at 0.2% (higher than 8% of all known vulnerabilities).
Official description
The IDC SFX2100 Satellite Receiver sets overly permissive file system permissions on the monitor user's home directory. The directory is configured with permissions 0777, granting read, write, and execute access to all local users on the system, which may cause local privilege escalation depending on conditions of the system due to the presence of highly privileged processes and binaries residing within the affected directory.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| International Datacasting Corporation | SFX2100 Satellite Receiver | SFX2100 |
Weakness: CWE-269 · Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N