Vulnerability · Published Aug 26, 2026 · Assigned by Danfoss

CVE-2026-15203Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software

Critical 9.3

In plain English

A critical-severity security flaw in iC7-Automation SP from Danfoss. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.5% (higher than 42% of all known vulnerabilities).

Severity (CVSS 4.0)9.3Critical
Exploit odds (30 days)0.5%top 58.4% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms

Affected products (as reported)

VendorProductVersions
Danfoss iC7-Automation SP 0 – through 2025.3.3
Danfoss iC7-Marine 0 – through 2025.8.19
Danfoss iC7-Hybrid 0 – through 2025.10.300845

Weakness: CWE-1191 · Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L

References