Vulnerability · Published Oct 27, 2025 · Assigned by Centreon

CVE-2025-8432CentreonBI user account on the MBI server can execute commands as root by modifying script runned by the CRON

High 8.4

In plain English

A high-severity incorrect default permissions in Infra Monitoring from Centreon. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.4% (higher than 38% of all known vulnerabilities).

Severity (CVSS 3.1)8.4High
Exploit odds (30 days)0.4%top 62.3% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

Incorrect Default Permissions vulnerability in Centreon Infra Monitoring (MBI modules) allows Embedding Scripts within Scripts by CentreonBI user account on the MBI server This issue affects Infra Monitoring: from 24.10.0 before 24.10.6, from 24.04.0 before 24.04.9, from 23.10.0 before 23.10.15.

Affected products (as reported)

VendorProductVersions
Centreon Infra Monitoring 24.10.0 – before 24.10.624.04.0 – before 24.04.923.10.0 – before 23.10.15

Weakness: CWE-276 · Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H

References