Vulnerability · Published Apr 9, 2025 · Assigned by juniper
CVE-2025-30645Junos OS: SRX Series: Transmission of specific control traffic sent out of a DS-Lite tunnel results in flowd crash
High 7.5
In plain English
A high-severity null pointer dereference in Junos OS from Juniper Networks. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.4% (higher than 38% of all known vulnerabilities).
Official description
A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process, resulting in a Denial of Service (DoS). Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition. On all SRX platforms, when specific, valid control traffic needs to be sent out of a DS-Lite tunnel, a segmentation fault occurs within the flowd process, resulting in a network outage until the flowd process restarts. This issue affects Junos OS on SRX Series: * All versions before 21.2R3-S9, * from 21.4 before 21.4R3-S9, * from 22.2 before 22.2R3-S5, * from 22.4 before 22.4R3-S6, * from 23.2 before 23.2R2-S3, * from 23.4 before 23.4R2.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Juniper Networks | Junos OS | 0 – before 21.2R3-S921.4 – before 21.4R3-S922.2 – before 22.2R3-S522.4 – before 22.4R3-S623.2 – before 23.2R2-S323.4 – before 23.4R2 |
Weakness: CWE-476 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
References
- https://supportportal.juniper.net/JSA96455 vendor-advisory