Vulnerability · Published Mar 11, 2025 · Assigned by siemens
CVE-2025-27493
High 8.2
In plain English
A high-severity improper input validation in SiPass integrated AC5102 (ACC-G2) from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.2% (higher than 7% of all known vulnerabilities).
Official description
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize user input for specific commands on the telnet command line interface. This could allow an authenticated local administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | SiPass integrated AC5102 (ACC-G2) | 0 – before V6.4.9 |
| Siemens | SiPass integrated ACC-AP | 0 – before V6.4.9 |
Weakness: CWE-20 · Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H