Vulnerability · Published Oct 5, 2025 · Assigned by VulDB
CVE-2025-11293Belkin F9K1015 formConnectionSetting buffer overflow
High 8.8
In plain English
A high-severity buffer overflow in F9K1015 from Belkin. Proof-of-concept exploit code is public. The chance it is exploited in the next 30 days is estimated at 1.1% (higher than 66% of all known vulnerabilities).
Official description
A security vulnerability has been detected in Belkin F9K1015 1.00.10. Affected by this vulnerability is an unknown functionality of the file /goform/formConnectionSetting. The manipulation of the argument max_Conn leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Affected products (as reported)
Weakness: CWE-120, CWE-119 · Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
References
- VDB-327174 | Belkin F9K1015 formConnectionSetting buffer overflow vdb-entry, technical-description
- VDB-327174 | CTI Indicators (IOB, IOC, IOA) signature, permissions-required
- Submit #661296 | Belkin F9K1015 1.00.10 Buffer Overflow third-party-advisory
- https://github.com/panda666-888/vuls/blob/main/belkin/f9k1015/formConnectionSetting.md related
- https://github.com/panda666-888/vuls/blob/main/belkin/f9k1015/formConnectionSetting.md#poc exploit