Vulnerability · Published Jul 9, 2024 · Assigned by siemens
CVE-2024-39568
High 7.8
In plain English
A high-severity command injection in SINEMA Remote Connect Client from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.9% (higher than 60% of all known vulnerabilities).
Official description
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading proxy configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | SINEMA Remote Connect Client | 0 – before V3.2 HF1 |
Weakness: CWE-77 · Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C