Vulnerability · Published May 14, 2024 · Assigned by siemens

CVE-2024-33494

Medium 6.5

In plain English

A medium-severity insufficient verification of data authenticity in SIMATIC RTLS Locating Manager from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.3% (higher than 20% of all known vulnerabilities).

Severity (CVSS 3.1)6.5Medium
Exploit odds (30 days)0.3%top 79.9% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing.

Affected products (as reported)

VendorProductVersions
Siemens SIMATIC RTLS Locating Manager 0 – before V3.0.1.1
Siemens SIMATIC RTLS Locating Manager 0 – before V3.0.1.1
Siemens SIMATIC RTLS Locating Manager 0 – before V3.0.1.1
Siemens SIMATIC RTLS Locating Manager 0 – before V3.0.1.1
Siemens SIMATIC RTLS Locating Manager 0 – before V3.0.1.1
Siemens SIMATIC RTLS Locating Manager 0 – before V3.0.1.1
Siemens SIMATIC RTLS Locating Manager 0 – before V3.0.1.1

Weakness: CWE-345 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C