Vulnerability · Published Jan 9, 2024 · Assigned by siemens

CVE-2023-49251

High 8.8

In plain English

A high-severity authorization bypass via user-controlled key in SIMATIC CN 4100 from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.5% (higher than 45% of all known vulnerabilities).

Severity (CVSS 3.1)8.8High
Exploit odds (30 days)0.5%top 55.1% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application allows an attacker to add their own login credentials to the device. This allows an attacker to remotely login as root and take control of the device even after the affected device is fully set up.

Affected products (as reported)

VendorProductVersions
Siemens SIMATIC CN 4100 All versions < V2.7

Weakness: CWE-639 · Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C

References