Vulnerability · Published Feb 13, 2024 · Assigned by siemens
CVE-2023-49125
High 7.8
In plain English
A high-severity out-of-bounds read in Parasolid V35.0 from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.2% (higher than 10% of all known vulnerabilities).
Official description
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.263), Parasolid V35.1 (All versions < V35.1.252), Parasolid V36.0 (All versions < V36.0.198), Solid Edge SE2023 (All versions < V223.0 Update 11), Solid Edge SE2024 (All versions < V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Parasolid V35.0 | 0 – before V35.0.263 |
| Siemens | Parasolid V35.1 | 0 – before V35.1.252 |
| Siemens | Parasolid V36.0 | 0 – before V36.0.198 |
| Siemens | Solid Edge SE2023 | 0 – before V223.0 Update 11 |
| Siemens | Solid Edge SE2024 | 0 – before V224.0 Update 3 |
Weakness: CWE-125 · Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H