Vulnerability · Published Aug 8, 2023 · Assigned by siemens
CVE-2023-38529
High 7.8
In plain English
A high-severity out-of-bounds read in Parasolid V34.1 from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.2% (higher than 11% of all known vulnerabilities).
Official description
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Parasolid V34.1 | 0 – before V34.1.258 |
| Siemens | Parasolid V35.0 | 0 – before V35.0.254 |
| Siemens | Parasolid V35.1 | 0 – before V35.1.184 |
| Siemens | Teamcenter Visualization V14.1 | 0 – before * |
| Siemens | Teamcenter Visualization V14.2 | 0 – before V14.2.0.12 |
| Siemens | Teamcenter Visualization V14.3 | 0 – before V14.3.0.9 |
| Siemens | Teamcenter Visualization V2312 | 0 – before V2312.0004 |
Weakness: CWE-125 · Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C