Vulnerability · Published May 3, 2024 · Assigned by zdi
CVE-2023-38123Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability
High 7.5
In plain English
A high-severity missing authentication in Ignition from Inductive Automation. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.2% (higher than 67% of all known vulnerabilities).
Official description
Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the server configuration. The issue results from the lack of authentication prior to allowing access to password change functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20540.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Inductive Automation | Ignition | 8.1.24 |
Weakness: CWE-306 · Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
References
- ZDI-23-1014 x_research-advisory
- vendor-provided URL vendor-advisory