Vulnerability · Published Sep 12, 2023 · Assigned by siemens
CVE-2023-38076
High 7.8
In plain English
A high-severity heap buffer overflow in JT2Go from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.4% (higher than 38% of all known vulnerabilities).
Official description
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | JT2Go | All versions < V14.3.0.1 |
| Siemens | Teamcenter Visualization V13.3 | All versions < V13.3.0.12 |
| Siemens | Teamcenter Visualization V14.0 | All versions |
| Siemens | Teamcenter Visualization V14.1 | All versions < V14.1.0.11 |
| Siemens | Teamcenter Visualization V14.2 | All versions < V14.2.0.6 |
| Siemens | Teamcenter Visualization V14.3 | All versions < V14.3.0.1 |
| Siemens | Tecnomatix Plant Simulation V2201 | All versions < V2201.0010 |
| Siemens | Tecnomatix Plant Simulation V2302 | All versions < V2302.0004 |
Weakness: CWE-122 · Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C