Vulnerability · Published Jul 14, 2023 · Assigned by juniper

CVE-2023-36838Junos OS: SRX Series: A flowd core occurs when running a low privileged CLI command

Medium 5.5

In plain English

A medium-severity out-of-bounds read in Junos OS from Juniper Networks. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.2% (higher than 8% of all known vulnerabilities).

Severity (CVSS 3.1)5.5Medium
Exploit odds (30 days)0.2%top 92.0% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

An Out-of-bounds Read vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on SRX Series allows a local, authenticated attacker with low privileges, to cause a Denial of Service (DoS). If a low privileged user executes a specific CLI command, flowd which is responsible for traffic forwarding in SRX crashes and generates a core dump. This will cause temporary traffic interruption until the flowd process is restarted automatically. Continued execution of this command will lead to a sustained DoS. This issue affects Juniper Networks Junos OS on SRX Series: All versions prior to 20.2R3-S7; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3-S6; 21.1 versions prior to 21.1R3-S5; 21.2 versions prior to 21.2R3-S4; 21.3 versions prior to 21.3R3-S4; 21.4 versions prior to 21.4R3-S3; 22.1 versions prior to 22.1R3-S1; 22.2 versions prior to 22.2R3; 22.3 versions prior to 22.3R2; 22.4 versions prior to 22.4R1-S1, 22.4R2.

Affected products (as reported)

VendorProductVersions
Juniper Networks Junos OS unspecified – before 20.2R3-S720.3 – before 20.3*20.4 – before 20.4R3-S621.1 – before 21.1R3-S521.2 – before 21.2R3-S421.3 – before 21.3R3-S421.4 – before 21.4R3-S322.1 – before 22.1R3-S1

Weakness: CWE-125 · Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

References