Vulnerability · Published Jun 13, 2023 · Assigned by siemens

CVE-2023-29129

Critical 9.1

In plain English

A critical-severity security flaw in Mendix SAML (Mendix 7 compatible) from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.9% (higher than 59% of all known vulnerabilities).

Severity (CVSS 3.1)9.1Critical
Exploit odds (30 days)0.9%top 40.5% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.3 < V1.18.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.16.4 < V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.4.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.2.0 < V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.3.1 < V3.6.1), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.1.9 < V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.3.0 < V3.6.0), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.1.8 < V3.3.0), Mendix SAML (Mendix 9.12/9.18 compatible, New Track) (All versions >= V3.3.1 < V3.3.15), Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.14), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions >= V3.1.9 < V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions >= V3.1.8 < V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application. This CVE entry describes the incomplete fix for CVE-2023-25957 in a specific non default configuration.

Affected products (as reported)

VendorProductVersions
Siemens Mendix SAML (Mendix 7 compatible) All versions >= V1.17.3 < V1.18.0
Siemens Mendix SAML (Mendix 7 compatible) All versions >= V1.16.4 < V1.17.3
Siemens Mendix SAML (Mendix 8 compatible) All versions >= V2.3.0 < V2.4.0
Siemens Mendix SAML (Mendix 8 compatible) All versions >= V2.2.0 < V2.3.0
Siemens Mendix SAML (Mendix 9 latest compatible, New Track) All versions >= V3.3.1 < V3.6.1
Siemens Mendix SAML (Mendix 9 latest compatible, New Track) All versions >= V3.1.9 < V3.3.1
Siemens Mendix SAML (Mendix 9 latest compatible, Upgrade Track) All versions >= V3.3.0 < V3.6.0
Siemens Mendix SAML (Mendix 9 latest compatible, Upgrade Track) All versions >= V3.1.8 < V3.3.0
Siemens Mendix SAML (Mendix 9.12/9.18 compatible, New Track) All versions >= V3.3.1 < V3.3.15
Siemens Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track) All versions >= V3.3.0 < V3.3.14
Siemens Mendix SAML (Mendix 9.6 compatible, New Track) All versions >= V3.1.9 < V3.2.7
Siemens Mendix SAML (Mendix 9.6 compatible, Upgrade Track) All versions >= V3.1.8 < V3.2.6

Weakness: CWE-303 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C

References