Vulnerability · Published May 9, 2023 · Assigned by siemens
CVE-2023-29103
Medium 4.3
In plain English
A medium-severity security flaw in SIMATIC Cloud Connect 7 CC712 from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.4% (higher than 33% of all known vulnerabilities).
Official description
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | SIMATIC Cloud Connect 7 CC712 | All versions >= V2.0 < V2.1 |
| Siemens | SIMATIC Cloud Connect 7 CC712 | All versions < V2.1 |
| Siemens | SIMATIC Cloud Connect 7 CC716 | All versions >= V2.0 < V2.1 |
| Siemens | SIMATIC Cloud Connect 7 CC716 | All versions < V2.1 |
Weakness: CWE-259 · Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C