Vulnerability · Published Jul 5, 2023 · Assigned by CERTVDE

CVE-2023-2880Frauscher Sensortechnik Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability

High 7.5

In plain English

A high-severity path traversal in Diagnostic System FDS101 for FAdC/FAdCi from Frauscher Sensortechnik. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.0% (higher than 62% of all known vulnerabilities).

Severity (CVSS 3.1)7.5High
Exploit odds (30 days)1.0%top 37.5% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device.

Affected products (as reported)

VendorProductVersions
Frauscher Sensortechnik Diagnostic System FDS101 for FAdC/FAdCi 0 – through 1.3.3

Weakness: CWE-22 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

References