Vulnerability · Published Jan 25, 2023 · Assigned by INCIBE
CVE-2023-0321Disclosure of Sensitive Information on Campbell Scientific Products
Critical 9.1
In plain English
A critical-severity information exposure in CR1000 from Campbell Scientific. Proof-of-concept exploit code is public. The chance it is exploited in the next 30 days is estimated at 0.9% (higher than 59% of all known vulnerabilities).
Official description
Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Campbell Scientific | CR6 | all version |
| Campbell Scientific | CR300 | all version |
| Campbell Scientific | CR800 | all version |
| Campbell Scientific | CR1000 | all version |
| Campbell Scientific | CR3000 | all version |
Weakness: CWE-200 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N