Vulnerability · Published Dec 13, 2022 · Assigned by siemens

CVE-2022-46350

Medium 6.1

In plain English

A medium-severity security flaw in SCALANCE X204RNA EEC (HSR) from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.5% (higher than 41% of all known vulnerabilities).

Severity (CVSS 3.1)6.1Medium
Exploit odds (30 days)0.5%top 58.7% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.

Affected products (as reported)

VendorProductVersions
Siemens SCALANCE X204RNA (HSR) All versions < V3.2.7
Siemens SCALANCE X204RNA (PRP) All versions < V3.2.7
Siemens SCALANCE X204RNA EEC (HSR) All versions < V3.2.7
Siemens SCALANCE X204RNA EEC (PRP) All versions < V3.2.7
Siemens SCALANCE X204RNA EEC (PRP/HSR) All versions < V3.2.7

Weakness: CWE-80 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

References