Vulnerability · Published Dec 12, 2023 · Assigned by siemens
CVE-2022-42784
High 7.6
In plain English
A high-severity security flaw in LOGO! 12/24RCE from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.2% (higher than 16% of all known vulnerabilities).
Official description
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | LOGO! 12/24RCE | V8.3 – before * |
| Siemens | LOGO! 12/24RCEo | V8.3 – before * |
| Siemens | LOGO! 230RCE | V8.3 – before * |
| Siemens | LOGO! 230RCEo | V8.3 – before * |
| Siemens | LOGO! 24CE | V8.3 – before * |
| Siemens | LOGO! 24CEo | V8.3 – before * |
| Siemens | LOGO! 24RCE | V8.3 – before * |
| Siemens | LOGO! 24RCEo | V8.3 – before * |
| Siemens | SIPLUS LOGO! 12/24RCE | V8.3 – before * |
| Siemens | SIPLUS LOGO! 12/24RCEo | V8.3 – before * |
| Siemens | SIPLUS LOGO! 230RCE | V8.3 – before * |
| Siemens | SIPLUS LOGO! 230RCEo | V8.3 – before * |
| Siemens | SIPLUS LOGO! 24CE | V8.3 – before * |
| Siemens | SIPLUS LOGO! 24CEo | V8.3 – before * |
| Siemens | SIPLUS LOGO! 24RCE | V8.3 – before * |
| Siemens | SIPLUS LOGO! 24RCEo | V8.3 – before * |
Weakness: CWE-1319 · Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C