CVE-2022-40202

Critical 9.8

In plain English

A critical-severity missing authentication in InfraSuite Device Master from Delta Electronics. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.6% (higher than 76% of all known vulnerabilities).

Severity (CVSS 3.1)9.8Critical
Exploit odds (30 days)1.6%top 23.6% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.

Affected products (as reported)

VendorProductVersions
Delta Electronics InfraSuite Device Master 0 – through 00.00.01a

Weakness: CWE-306 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H