Vulnerability · Published Oct 11, 2022 · Assigned by siemens

CVE-2022-36362

High 7.5

In plain English

A high-severity improper input validation in LOGO! 12/24RCE from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.0% (higher than 64% of all known vulnerabilities).

Severity (CVSS 3.1)7.5High
Exploit odds (30 days)1.0%top 36.1% of all CVEs
Exploited in the wildNo reportsnot in CISA KEV
Attack toolingNoneno public tooling known

Official description

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device.

Affected products (as reported)

VendorProductVersions
Siemens LOGO! 12/24RCE All versions
Siemens LOGO! 12/24RCE All versions
Siemens LOGO! 12/24RCEo All versions
Siemens LOGO! 12/24RCEo All versions
Siemens LOGO! 230RCE All versions
Siemens LOGO! 230RCE All versions
Siemens LOGO! 230RCEo All versions
Siemens LOGO! 230RCEo All versions
Siemens LOGO! 24CE All versions
Siemens LOGO! 24CE All versions
Siemens LOGO! 24CEo All versions
Siemens LOGO! 24CEo All versions
Siemens LOGO! 24RCE All versions
Siemens LOGO! 24RCE All versions
Siemens LOGO! 24RCEo All versions
Siemens LOGO! 24RCEo All versions
Siemens SIPLUS LOGO! 12/24RCE All versions
Siemens SIPLUS LOGO! 12/24RCE All versions
Siemens SIPLUS LOGO! 12/24RCEo All versions
Siemens SIPLUS LOGO! 12/24RCEo All versions
Siemens SIPLUS LOGO! 230RCE All versions
Siemens SIPLUS LOGO! 230RCE All versions
Siemens SIPLUS LOGO! 230RCEo All versions
Siemens SIPLUS LOGO! 230RCEo All versions
Siemens SIPLUS LOGO! 24CE All versions
Siemens SIPLUS LOGO! 24CE All versions
Siemens SIPLUS LOGO! 24CEo All versions
Siemens SIPLUS LOGO! 24CEo All versions
Siemens SIPLUS LOGO! 24RCE All versions
Siemens SIPLUS LOGO! 24RCE All versions

Weakness: CWE-20 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C