Vulnerability · Published Jun 1, 2022 · Assigned by siemens

CVE-2022-29875

Critical 9.8

In plain English

A critical-severity unsafe deserialization in Biograph Horizon PET/CT Systems from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.9% (higher than 79% of all known vulnerabilities).

Severity (CVSS NVD)9.8Critical
Exploit odds (30 days)1.9%top 20.6% of all CVEs
Exploited in the wildNo reportsnot in CISA KEV
Attack toolingNoneno public tooling known

Official description

A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable.

Affected products (as reported)

VendorProductVersions
Siemens Biograph Horizon PET/CT Systems All VJ30 versions < VJ30C-UD01
Siemens MAGNETOM Family NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A
Siemens MAMMOMAT Revelation All VC20 versions < VC20D
Siemens NAEOTOM Alpha All VA40 versions < VA40 SP2
Siemens SOMATOM X.cite All versions < VA30 SP5 or VA40 SP2
Siemens SOMATOM X.creed All versions < VA30 SP5 or VA40 SP2
Siemens SOMATOM go.All All versions < VA30 SP5 or VA40 SP2
Siemens SOMATOM go.Now All versions < VA30 SP5 or VA40 SP2
Siemens SOMATOM go.Open Pro All versions < VA30 SP5 or VA40 SP2
Siemens SOMATOM go.Sim All versions < VA30 SP5 or VA40 SP2
Siemens SOMATOM go.Top All versions < VA30 SP5 or VA40 SP2
Siemens SOMATOM go.Up All versions < VA30 SP5 or VA40 SP2
Siemens Symbia E/S All VB22 versions < VB22A-UD03
Siemens Symbia Evo All VB22 versions < VB22A-UD03
Siemens Symbia Intevo All VB22 versions < VB22A-UD03
Siemens Symbia T All VB22 versions < VB22A-UD03
Siemens Symbia.net All VB22 versions < VB22A-UD03
Siemens syngo.via VB10 All versions
Siemens syngo.via VB20 All versions
Siemens syngo.via VB30 All versions
Siemens syngo.via VB40 All versions < VB40B HF06
Siemens syngo.via VB50 All versions
Siemens syngo.via VB60 All versions < VB60B HF02

Weakness: CWE-502