Vulnerability · Published Sep 14, 2021 · Assigned by siemens

CVE-2021-37183

Medium 6.5

In plain English

A medium-severity improper access control in SINEMA Remote Connect Server from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.4% (higher than 31% of all known vulnerabilities).

Severity (CVSS 3.1)6.5Medium
Exploit odds (30 days)0.4%top 68.6% of all CVEs
Exploited in the wildNo reportsCISA SSVC: none
Attack toolingNoneno public tooling known

Official description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software allows sending send-to-sleep notifications to the managed devices. An unauthenticated attacker in the same network of the affected system can abuse these notifications to cause a Denial-of-Service condition in the managed devices.

Affected products (as reported)

VendorProductVersions
Siemens SINEMA Remote Connect Server All versions < V3.0 SP2

Weakness: CWE-284 · Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

References