Vulnerability · Published Feb 19, 2021 · Assigned by Mitsubishi

CVE-2021-20588

High 7.5

In plain English

A high-severity security flaw in CPU Module Logging Configuration Tool from Mitsubishi Electric Corporation. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 6.9% (higher than 94% of all known vulnerabilities).

Severity (CVSS 3.1)7.5High
Exploit odds (30 days)6.9%top 5.9% of all CVEs
Exploited in the wildNo reportsnot in CISA KEV
Attack toolingNoneno public tooling known

Official description

Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior, and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition on the software products, and possibly to execute a malicious code on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.

Affected products (as reported)

VendorProductVersions
Mitsubishi Electric Corporation CPU Module Logging Configuration Tool 1.112R and prior
Mitsubishi Electric Corporation CW Configurator 1.011M and prior
Mitsubishi Electric Corporation Data Transfer 3.44W and prior
Mitsubishi Electric Corporation EZSocket 5.4 and prior
Mitsubishi Electric Corporation FR Configurator all versions
Mitsubishi Electric Corporation FR Configurator SW3 all versions
Mitsubishi Electric Corporation FR Configurator2 1.24A and prior
Mitsubishi Electric Corporation GT Designer3 Version1(GOT1000) 1.250L and prior
Mitsubishi Electric Corporation GT Designer3 Version1(GOT2000) 1.250L and prior
Mitsubishi Electric Corporation GT SoftGOT1000 Version3 3.245F and prior
Mitsubishi Electric Corporation GT SoftGOT2000 Version1 1.250L and prior
Mitsubishi Electric Corporation GX Configurator-DP 7.14Q and prior
Mitsubishi Electric Corporation GX Configurator-QP all versions
Mitsubishi Electric Corporation GX Developer 8.506C and prior
Mitsubishi Electric Corporation GX Explorer all versions
Mitsubishi Electric Corporation GX IEC Developer all versions
Mitsubishi Electric Corporation GX LogViewer 1.115U and prior
Mitsubishi Electric Corporation GX RemoteService-I all versions
Mitsubishi Electric Corporation GX Works2 1.597X and prior
Mitsubishi Electric Corporation GX Works3 1.070Y and prior
Mitsubishi Electric Corporation iQ Monozukuri ANDON (Data Transfer) 1.003D and prior
Mitsubishi Electric Corporation iQ Monozukuri Process Remote Monitoring (Data Transfer) 1.002C and prior
Mitsubishi Electric Corporation M_CommDTM-HART all versions
Mitsubishi Electric Corporation M_CommDTM-IO-Link 1.03D and prior
Mitsubishi Electric Corporation MELFA-Works 4.4 and prior
Mitsubishi Electric Corporation MELSEC WinCPU Setting Utility all versions
Mitsubishi Electric Corporation MELSOFT EM Software Development Kit (EM Configurator) 1.015R and prior
Mitsubishi Electric Corporation MELSOFT Navigator 2.74C and prior
Mitsubishi Electric Corporation MH11 SettingTool Version2 2.004E and prior
Mitsubishi Electric Corporation MI Configurator 1.004E and prior

Weakness: CWE-130 · Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

References