Vulnerability · Published Jan 13, 2021 · Assigned by icscert
CVE-2020-27267
Critical 9.1
In plain English
A critical-severity use-after-free in GE Digital Industrial Gateway Server. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 6.0% (higher than 93% of all known vulnerabilities).
Official description
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| n/a | PTC Kepware KEPServerEX | v6.0 to v6.9 |
| n/a | ThingWorx Kepware Server | v6.8 and v6.9 |
| n/a | ThingWorx Industrial Connectivity | All versions |
| n/a | OPC-Aggregator | All versions |
| n/a | Rockwell Automation KEPServer Enterprise | All versions |
| n/a | GE Digital Industrial Gateway Server | v7.68.804v7.66 |
| n/a | Software Toolbox TOP Server | All 6.x versions |
Weakness: CWE-416
References
- https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 x_refsource_MISC