Vulnerability · Published Jan 12, 2021 · Assigned by siemens
CVE-2020-15800
Critical 9.8
In plain English
A critical-severity heap buffer overflow in SCALANCE X-200 switch family (incl. SIPLUS NET variants) from Siemens. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.7% (higher than 77% of all known vulnerabilities).
Official description
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens | SCALANCE X-200 switch family (incl. SIPLUS NET variants) | All versions < V5.2.5 |
| Siemens | SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) | All versions < V5.5.0 |
| Siemens | SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) | All versions < V4.1.0 |
Weakness: CWE-122
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf x_refsource_MISC