Vulnerability · Published Apr 15, 2020 · Assigned by icscert
CVE-2020-10611
Critical 9.8
In plain English
A critical-severity type confusion in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 5.2% (higher than 93% of all known vulnerabilities).
Official description
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| n/a | Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 | Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 |
Weakness: CWE-843
References
- https://www.us-cert.gov/ics/advisories/icsa-20-105-03 x_refsource_MISC
- https://www.zerodayinitiative.com/advisories/ZDI-20-549/ x_refsource_MISC