Vulnerability · Published Jun 24, 2020 · Assigned by Alias

CVE-2020-10276RVD#2558: Default credentials on SICK PLC allows disabling safety features

Critical 9.8

In plain English

A critical-severity hard-coded credentials in MiR100 from Mobile Industrial Robots A/S. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.5% (higher than 74% of all known vulnerabilities).

Severity (CVSS 3.0)9.8Critical
Exploit odds (30 days)1.5%top 25.6% of all CVEs
Exploited in the wildNo reportsnot in CISA KEV
Attack toolingNoneno public tooling known

Official description

The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.

Affected products (as reported)

VendorProductVersions
Mobile Industrial Robots A/S MiR100 v2.8.1.1 and before

Weakness: CWE-798 · Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

References