Vulnerability · Published Jun 24, 2020 · Assigned by Alias

CVE-2020-10270RVD#2557: Hardcoded Credentials on MiRX00 Control Dashboard

Critical 9.8

In plain English

A critical-severity hard-coded credentials in MiR100 from Mobile Industrial Robots A/S. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 1.7% (higher than 77% of all known vulnerabilities).

Severity (CVSS 3.0)9.8Critical
Exploit odds (30 days)1.7%top 23.3% of all CVEs
Exploited in the wildNo reportsnot in CISA KEV
Attack toolingNoneno public tooling known

Official description

Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.

Affected products (as reported)

VendorProductVersions
Mobile Industrial Robots A/S MiR100 v2.8.1.1 and before

Weakness: CWE-798 · Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

References