Vulnerability · Published Sep 9, 2020 · Assigned by siemens
CVE-2020-10051
High 7.8
In plain English
A high-severity security flaw in SIMATIC RTLS Locating Manager from Siemens AG. There are no confirmed reports of exploitation so far. The chance it is exploited in the next 30 days is estimated at 0.3% (higher than 26% of all known vulnerabilities).
Severity (CVSS NVD)7.8High
Exploit odds (30 days)0.3%top 73.9% of all CVEs
Exploited in the wildNo reportsnot in CISA KEV
Attack toolingNoneno public tooling known
Official description
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service.
Affected products (as reported)
| Vendor | Product | Versions |
|---|---|---|
| Siemens AG | SIMATIC RTLS Locating Manager | All versions < V2.10.2 |
Weakness: CWE-428
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf x_refsource_MISC